Manifold Hydraulic / Pneumatic / Outlets 1 Side / 1 Inlet

Manifold Hydraulic / Pneumatic / Outlets 1 Side / 1 Inlet

Click on this image to zoom in.

Click on this image to zoom in.

  • Manifold Hydraulic / Pneumatic / Outlets 1 Side / 1 Inlet
  • Manifold Hydraulic / Pneumatic / Outlets 1 Side / 1 Inlet
  • Manifold Hydraulic / Pneumatic / Outlets 1 Side / 1 Inlet
  • Manifold Hydraulic / Pneumatic / Outlets 1 Side / 1 Inlet

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Manifold Hydraulic/Pneumatic/Outlets 1 Side/1 Inlet:Related Image

UsageType Material Surface TreatmentMax. Operating Pressure
Pitch (P) StandardPitch (P) Configurable
25x32 Sq.30x35 Sq.15 Sq.20 Sq.30 Sq.40 Sq.25x32 Sq.30x35 Sq.20 Sq.30 Sq.40 Sq.
HydraulicBMZSBMZF-----BMZFP---EN 1.0038 Equiv.Trivalent Chromate20.6MPa≈210kgf/cm2 or less
BMZSMBMZFM----BMZSMPBMZFMP---Electroless Nickel Plating
BMZSRBMZFR----BMZSRPBMZFRP---EN 1.4301 Equiv.-
Pneumatic--BMZASBMZAFCBMZAFBMZAFL--BMZAFCPBMZAFPBMZAFLPEN AW-5052 Equiv.-1MPa≈10kgf/cm2 or less
--BMZASABMZAFCABMZAFABMZAFLA--BMZAFCAPBMZAFAPBMZAFLAPClear Anodize
Material of 15 Sq. is EN AW-6063 Equiv.

Specifications

Part Number-Q-G-P  
BMZF4
BMZFP3
G-BMZFP3
-
-
-
Q1
Q2
Q2
-
-
-
G2
G2
G2

-
-

P30
P30
 

(G Thread)
Part NumberRc (PT), M (Coarse) SelectionPitch PNumber of Pitches
N
Total Number of Q and G ThreadsABEFXYMounting Hole Dimension
TypeNumber of CircuitsQGStandardConfigurable 1mm IncrementdDh
Hydraulic (25x32 Sq.)11 (1/8)
2 (1/4)
1 (1/8)
2 (1/4)
2520~50
Specify within NxP≤140.
02253220201565.59.55.5
Pitch Standard
BMZS
BMZSM
BMZSR
Pitch Configurable

BMZSMP
BMZS
RP
213
324
435
546
Hydraulic (30x35 Sq.)11 (1/8)
2 (1/4)
3 (3/8)
1 (1/8)
2 (1/4)
3 (3/8)
4 (1/2)
3525~50
Specify within NxP≤120.
02303525221576.6116.5
Pitch Standard
BMZF
BMZFM
BMZFR
Pitch Configurable
BMZFP
BMZFMP
BMZ
FRP
21320
324
435
53046
Pneumatic (15 Sq.)1M3 (M3)
M4 (M4)
5 (M5)
5 (M5)15-021515151053.54.3--
Pitch Standard
BMZAS
B
MZASA
 213
324
435
546
Pneumatic (20 Sq.)11 (1/8)
M3 (M3)
M4 (M4)
5 (M5)*
1 (1/8)
5 (M5)*
1515~50
When 5 (M5) is selected for G, specify within NxP≤70.
When 1 (1/8) is selected for G, specify within NxP≤130.
0220202013545.5--
Pitch Standard
BMZAFC
BMZAFCA
Pitch Configurable
BMZAFCP
BMZAFCAP
213
324
435
5*46
Pneumatic (30 Sq.)11 (1/8)
2 (1/4)
5 (M5)*
1 (1/8)
2 (1/4)
5 (M5)*
2520~50
When 5 (M5) is selected for G, spwecify within NxP≤70.
When 1 (1/8) is selected for G, specify within NxP≤130.
When 1(1/8) or 2 (1/4) is selected for G, specify within NxP≤130.
02303020207.575.59.55.5
Pitch Standard
BMZAF
BMZAFA
Pitch Configurable
BMZAFP
BMZAFAP
213
324
435
5*46
Pneumatic (40 Sq.)11 (1/8)
2 (1/4)
3 (3/8)
2 (1/4)
3 (3/8)
4 (1/2)
3025~50
specify within N+P≤130
0240402525776.6116.5
Pitch Standard
BMZAFL
BMZAFLA
Pitch Configurable
BMZAFLP
BMZAFLAP
213
324
435
546
By inserting "G-" before part number, the thread type can be changed to the G (PF) Thread as part of ordering. (Ex.: G-BMZF) For ordering, see the Ordering Example. For "G-..." 5 (M5) is not available.
For Q and G, specify 1, 2, 3, 4, 5, M3 or M4 indicated before ( ). Single Circuit is not available for Pitch Configurable Type.
When * marked 5 pneumatic outlet port configuration is selected from 20 Sq. / 30 Sq., 5 (M5) is not available for "G-...". Mounting holes will be through holes for Pneumatic 15 and 20 Sq. Types.

Alterations

Manifold Hydraulic/Pneumatic/Outlets 1 Side/1 Inlet:Related Image

Part Number:  

    3D preview is not available, because the part number has not yet been determined.

  • In order to open the 3D preview, the part number must be fixed.
Loading...
Part Number
BMZF1-Q[1,​2,​3]-G[1,​2,​3,​4]
BMZF2-Q[1,​2,​3]-G[1,​2,​3,​4]
BMZF3-Q[1,​2,​3]-G[1,​2,​3,​4]
BMZF4-Q[1,​2,​3]-G[1,​2,​3,​4]
BMZF5-Q[1,​2,​3]-G[1,​2,​3,​4]
BMZFP2-Q[1,​2,​3]-G[1,​2,​3,​4]-P[20-50/1]
BMZFP3-Q[1,​2,​3]-G[1,​2,​3,​4]-P[20-50/1]
BMZFP4-Q[1,​2,​3]-G[1,​2,​3,​4]-P[20-50/1]
BMZFP5-Q[1,​2,​3]-G[1,​2,​3,​4]-P[25-50/1]
BMZS1-Q[1,​2]-G[1,​2]
BMZS2-Q[1,​2]-G[1,​2]
BMZS3-Q[1,​2]-G[1,​2]
BMZS4-Q[1,​2]-G[1,​2]
BMZS5-Q[1,​2]-G[1,​2]
G-BMZF1-Q[1,​2,​3]-G[1,​2,​3,​4]
G-BMZF2-Q[1,​2,​3]-G[1,​2,​3,​4]
G-BMZF3-Q[1,​2,​3]-G[1,​2,​3,​4]
G-BMZF4-Q[1,​2,​3]-G[1,​2,​3,​4]
G-BMZF5-Q[1,​2,​3]-G[1,​2,​3,​4]
G-BMZFP2-Q[1,​2,​3]-G[1,​2,​3,​4]-P[20-50/1]
G-BMZFP3-Q[1,​2,​3]-G[1,​2,​3,​4]-P[20-50/1]
G-BMZFP4-Q[1,​2,​3]-G[1,​2,​3,​4]-P[20-50/1]
G-BMZFP5-Q[1,​2,​3]-G[1,​2,​3,​4]-P[20-50/1]
G-BMZS1-Q[1,​2]-G[1,​2]
G-BMZS2-Q[1,​2]-G[1,​2]
G-BMZS3-Q[1,​2]-G[1,​2]
G-BMZS4-Q[1,​2]-G[1,​2]
G-BMZS5-Q[1,​2]-G[1,​2]
Part NumberMinimum order quantityVolume Discount
Standard
Shipping Days
?
RoHSShape Material Surface Treatment Block Size
(mm)
Number of Circuits
(Circuits)
Thread Size / Type Pitch P
(mm)
Pitch Standard / Configurable Application Thread Dia. Selection [G] 1 (1/8) 2 (1/4) 3 (3/8) 4 (1/2) 5 (M5) Thread Dia. Selection [QM] 3 (M3) 4 (M4) Thread Dia. Selection [Q] 1 (1/8) 2 (1/4) 3 (3/8) 5 (M5)
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 351Standard Thread {PT, m (Coarse) Thread}35Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 352Standard Thread {PT, m (Coarse) Thread}35Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 353Standard Thread {PT, m (Coarse) Thread}35Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 354Standard Thread {PT, m (Coarse) Thread}35Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 9 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 355Standard Thread {PT, m (Coarse) Thread}30Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 352Standard Thread {PT, m (Coarse) Thread}20 ~ 50Configurable TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 353Standard Thread {PT, m (Coarse) Thread}20 ~ 50Configurable TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 9 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 354Standard Thread {PT, m (Coarse) Thread}20 ~ 50Configurable TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 355Standard Thread {PT, m (Coarse) Thread}25 ~ 50Configurable TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 321Standard Thread {PT, m (Coarse) Thread}25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 322Standard Thread {PT, m (Coarse) Thread}25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 323Standard Thread {PT, m (Coarse) Thread}25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 324Standard Thread {PT, m (Coarse) Thread}25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 325Standard Thread {PT, m (Coarse) Thread}25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 351G (PF) Thread35Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 352G (PF) Thread35Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 353G (PF) Thread35Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 354G (PF) Thread35Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 355G (PF) Thread30Fixed TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 352G (PF) Thread20 ~ 50Configurable TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 353G (PF) Thread20 ~ 50Configurable TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 354G (PF) Thread20 ~ 50Configurable TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate30 x 355G (PF) Thread20 ~ 50Configurable TypeFor hydraulic / Water Pressure1 ~ 4-1 ~ 3
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 321G (PF) Thread25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 322G (PF) Thread25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 323G (PF) Thread25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 324G (PF) Thread25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2
1 13 Days 10Blind Lateral Hole, Upper HoleEN 1.0038 Equiv.Trivalent Chromate25 x 325G (PF) Thread25Fixed TypeFor hydraulic / Water Pressure1 ~ 2-1 ~ 2

Loading...

  1. 1

Complementary Products

Tech Support

Technical Support
Tel:+49 69 668173-0 / FAX:+49 69 668173-360