Chain Flex CF130.UL- Control Cable (CF130.02.03.UL-0.25SQ-3-84)

Chain Flex CF130.UL- Control Cable CF130.02.03.UL-0.25SQ-3-84

Product Details:

Manufacturer part number: CF130.02.03.UL-0.25SQ-3-84

Brand: IGUS

Price: 160.37

Delivery time: 5 Days


Technical Data:

Overall Length: 84 m

Conductor Cross Section: 0.25 mm2

Number Of Cores: 3 Core

Finished outer diameter: 5 mm

Rated Voltage: [300V] 300/300V


Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

CF130.02.03.UL-0.25SQ-3-84

Part Number
CF130.02.03.UL-0.25SQ-3-84
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
RoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Grounding Wire Minimum bending radius while running (Stroke Length: less than 10 m)
(mm)
Minimum bend radius while running (stroke length: More than 10 m)
(mm)
Minimum bending radius when fixed
(mm)
Conductor resistance
(Ω/km)
Reference allowable current value (30°C)
(A)

160.37 €

1 5 Days 10840.2535[300V] 300/300V[N/A] N/A37.55025795

Loading...

  1. 1

Basic information

Shield N/A Representative Standard UL / CE / CSA(c-UL) Sheath (outer coating) color Gray
Sheath (outer coating) material Low adhesiveness PVC admixture Insulation body materials TPE admixture Free span maximum running speed(m/s) 3
Slide maximum running speed(m/s) 2 Maximum acceleration(m/s2) 20 Stroke Up to 50m
Twist(° (1 m)) ±90 Other standards ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2012: Used of UL (AWM) cable allowed Other cable properties Flame retardant and silicone free
Note 1 Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors

This page is Chain Flex CF130.UL- Control Cable, part number CF130.02.03.UL-0.25SQ-3-84.
You can find the detail information about specifications and dimensions on part number CF130.02.03.UL-0.25SQ-3-84.

Variation of this product

Part Number
CF130.02.03.UL-0.25SQ-3-11
CF130.02.03.UL-0.25SQ-3-12
CF130.02.03.UL-0.25SQ-3-13
CF130.02.03.UL-0.25SQ-3-85
CF130.02.03.UL-0.25SQ-3-86
CF130.02.03.UL-0.25SQ-3-87
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
RoHSOverall Length
(m)
Conductor Cross Section
(mm2)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Rated Voltage Grounding Wire Minimum bending radius while running (Stroke Length: less than 10 m)
(mm)
Minimum bend radius while running (stroke length: More than 10 m)
(mm)
Minimum bending radius when fixed
(mm)
Conductor resistance
(Ω/km)
Reference allowable current value (30°C)
(A)

21.02 €

1 5 Days 10110.2535[300V] 300/300V[N/A] N/A37.55025795

22.92 €

1 5 Days 10120.2535[300V] 300/300V[N/A] N/A37.55025795

24.83 €

1 5 Days 10130.2535[300V] 300/300V[N/A] N/A37.55025795

162.28 €

1 5 Days 10850.2535[300V] 300/300V[N/A] N/A37.55025795

164.18 €

1 5 Days 10860.2535[300V] 300/300V[N/A] N/A37.55025795

166.09 €

1 5 Days 10870.2535[300V] 300/300V[N/A] N/A37.55025795

Tech Support