Type | Material | Surface Treatment | Max. Operating Pressure | |||||||||
Pitch (P) Standard | Pitch (P) Configurable | |||||||||||
20 Sq. | 30 Sq. | 40 Sq. | 50 Sq. | 60 Sq. | 70 Sq. | 30 Sq. | 40 Sq. | 50 Sq. | 60 Sq. | |||
BTLSB | BTLS | BTLSK | BTLSFL | BTLSFLK | BTLL | BTLSP | BTLSKP | BTLSFLP | BTLSFLKP | EN 1.0038 Equiv. | Trivalent Chromate | 20.6MPa≈210kgf/cm2 or less |
- | BTLSM | BTLSMK | BTLSFLM | BTLSFLKM | - | BTLSMP | BTLSMKP | - | - | Electroless Nickel Plating | ||
BTLSBR | BTLSR | BTLSRK | BTLSFLR | - | - | BTLSRP | BTLSRKP | - | - | EN 1.4301 Equiv. | - | |
- | BTLSS | - | - | - | - | - | - | - | - | EN 1.4401 Equiv. | ||
- | BTLSC | - | - | - | - | - | - | - | - | Brass | 1MPa≈10kgf/cm2 or less |
Part Number | - | Q | - | R | - | P | |||||
Type | Mounting Hole Change | Number of Circuits | |||||||||
BTLS BTLSFLP BTLA BTLAP G-BTLAP | NA T ZT ZT | 5 4 4 5 5 | - - - - - | Q3 Q4 Q2 Q2 Q2 | - - - - - | R2 R3 R1 R2 R2 | - - - | P50 P50 P50 | (G Thread) |
Part Number | Rc (PT), NPT Selection | Pitch P | Number of Pitches | Q, R | A | B | E | F | X | Y | Mounting Hole | ||||
Type | Mounting Hole Change | Number of Circuits | Q, R | Standard | Configurable 1mm Increment | N | Total Number of Threads | M | |||||||
(20 Sq.) | NA (Through) T (Tapped) ZT (Counterbore Tapped) | 1 | 1 (1/8) | - | - | 0 | 2 | 20 | 20 | 20 | 10 | 6 | 6 | M5 | |
Pitch Standard BTLSB BTLSBR | 2 | 25 | 1 | 4 | |||||||||||
3 | 2 | 6 | |||||||||||||
4 | 3 | 8 | |||||||||||||
5 | 4 | 10 | |||||||||||||
6 | 5 | 12 | |||||||||||||
7 | 6 | 14 | |||||||||||||
8 | 7 | 16 | |||||||||||||
(30 Sq.) | 1 | 1 (1/8) 2 (1/4) 3 (3/8) 1N (NPT1/8) 2N (NPT1/4) 3N (NPT3/8) | - | - | 0 | 2 | 30 | 30 | 20 | 15 | 7.5 | 7 | M6 | ||
Pitch Standard BTLS BTLSM BTLSR BTLSS BTLSC | Pitch Configurable BTLSP BTLSMP BTLSRP | 2 | 35 | 25~60 | 1 | 4 | |||||||||
3 | 2 | 6 | |||||||||||||
4 | 3 | 8 | |||||||||||||
5 | 4 | 10 | |||||||||||||
6 | 5 | 12 | |||||||||||||
7 | 6 | 14 | |||||||||||||
8 | 7 | 16 | |||||||||||||
(40 Sq.) | 1 | 1 (1/8) 2 (1/4) 3 (3/8) 1N (NPT1/8) 2N (NPT1/4) 3N (NPT3/8) | - | - | 0 | 2 | 40 | 40 | 20 | 20 | 7.5 | 7 | M6 | ||
Pitch Standard BTLSK BTLSMK BTLSRK | Pitch Configurable BTLSKP BTLSMKP BTLSRKP | 2 | 35 | 25~60 | 1 | 4 | |||||||||
3 | 2 | 6 | |||||||||||||
4 | 3 | 8 | |||||||||||||
5 | 4 | 10 | |||||||||||||
6 | 5 | 12 | |||||||||||||
7 | 6 | 14 | |||||||||||||
8 | 7 | 16 | |||||||||||||
(50 Sq.) | 1 | 2 (1/4) 3 (3/8) 4 (1/2) 6 (3/4) | - | - | 0 | 2 | 50 | 50 | 30 | 25 | 7.5 | 8 | M8 | ||
Pitch Standard BTLSFL BTLSFLM BTLSFLR | Pitch Configurable BTLSFLP | 2 | 60 | 35~60 | 1 | 4 | |||||||||
3 | 2 | 6 | |||||||||||||
4 | 3 | 8 | |||||||||||||
5 | 4 | 10 | |||||||||||||
6 | 5 | 12 | |||||||||||||
(60 Sq.) | 1 | 2 (1/4) 3 (3/8) 4 (1/2) 6 (3/4) | - | - | 0 | 2 | 60 | 60 | 30 | 30 | 7.5 | 8 | M8 | ||
Pitch Standard BTLSFLK BTLSFLKM | Pitch Configurable BTLSFLKP | 2 | 60 | 35~60 | 1 | 4 | |||||||||
3 | 2 | 6 | |||||||||||||
4 | 3 | 8 | |||||||||||||
5 | 4 | 10 | |||||||||||||
6 | 5 | 12 | |||||||||||||
(70 Sq.) | 1 | 6 (3/4) 8 (1) | - | - | 0 | 2 | 70 | 70 | 40 | 35 | 10 | 9 | M8 | ||
Pitch Standard BTLL | 2 | 60 | 1 | 4 | |||||||||||
3 | 2 | 6 | |||||||||||||
4 | 3 | 8 |
3D preview is not available, because the part number has not yet been determined.
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | RoHS | Material | Surface Treatment | Block Size (mm) | Number of Circuits (Circuits) | Thread Size / Type | Mounting Hole Change | Pitch P (mm) | Pitch Standard / Configurable | Application | Drawing Q Part Thread Dia. NPT Selection [Q] | Drawing R Part Thread Dia. NPT Selection [R] | Select a value for PT/PF Thread Dia. on Q (in Drawing). [Q] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1) | Select a value for PT/PF Thread Dia. on R (in Drawing). [R] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Electroless Nickel Plating | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Electroless Nickel Plating | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Electroless Nickel Plating | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Electroless Nickel Plating | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 1 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | - | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 1 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | - | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 1 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | - | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 9 Days | 10 | EN 1.0038 Equiv. | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 1 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | - | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 2 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 3 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 4 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 5 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 6 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 1 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | - | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 2 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 3 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 4 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 5 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 6 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 1 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | - | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 2 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 3 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 4 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 5 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 12 Days | 10 | Steel for General Structure | Electroless Nickel Plating | 50 x 50 | 6 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | - | - | 2 ~ 6 | 2 ~ 6 |
Loading...
Shape | Intlets - None Outlets - Top & Side |
---|
Configure
Basic Attributes
Material
Surface Treatment
Block Size(mm)
Number of Circuits(Circuits)
Thread Size / Type
Mounting Hole Change
Pitch P(mm)
Pitch Standard / Configurable
Application
Drawing Q Part Thread Dia. NPT Selection [Q]
Drawing R Part Thread Dia. NPT Selection [R]
Select a value for PT/PF Thread Dia. on Q (in Drawing). [Q] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1)
Select a value for PT/PF Thread Dia. on R (in Drawing). [R] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1)