RFID-coded Safety Sensor

RFID-coded Safety Sensor
[Specifications]
・Type of Operation: permanent operation
・Materials: PA
・Operating Current(mA): 40-700
・Protection Class: III

[Features]
・Unique actuator coding prevents tampering on doors
・Connect up to 32 sensors in series with the safety integrity remaining at the same level
・Switching status indication by LEDs
・Programmable any number of times for easy set-up
・Meets the new interface description CB24I from ZVEI

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
MN700S
MN701S
MN702S
MN703S
MN704S
MN705S
MN706S
MN707S
MN708S
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Design Electrical Connection - Plug Operating Voltage
(V)
Electrical Connection Accessories (Included)

133.86 €

1 4 Days coded targetConnector: 1 x M12; Moulded body: stainless steel (1.4301 / 304)20.4-26.4 DC-coded targetwashers: 4cover caps: 8

140.85 €

1 4 Days uniquely fully coded targetConnector: 1 x M12; Moulded body: stainless steel (1.4301 / 304)20.4-26.4 DC-uniquely fully coded target
washers: 4
cover caps: 8

140.85 €

1 4 Days codable targetConnector: 1 x M12; Moulded body: stainless steel (1.4301 / 304)20.4-26.4 DC-codable targetwashers: 4cover caps: 8

133.86 €

1 4 Days coded target-20.4-26.4 DCCable: 2 m, PVC; 6 x 0.5 mm²coded targetwashers: 4cover caps: 8

140.85 €

1 4 Days uniquely fully coded target-20.4-26.4 DCCable: 2 m, PVC; 8 x 0.34 mm²uniquely fully coded target
washers: 4
cover caps: 8

140.85 €

1 4 Days codable target-20.4-26.4 DCCable: 2 m, PVC; 8 x 0.34 mm²codable targetwashers: 4cover caps: 8

133.86 €

1 4 Days coded targetConnector: 1 x M12; Moulded body: stainless steel (1.4301 / 304)20.4-26.4 DC; ("supply class 2" to cULus)-coded targetwashers: 4cover caps: 8

140.85 €

1 4 Days uniquely fully coded targetConnector: 1 x M12; Moulded body: stainless steel (1.4301 / 304)20.4-26.4 DC; ("supply class 2" to cULus)-uniquely fully coded target
washers: 4
cover caps: 8

140.85 €

1 4 Days codable targetConnector: 1 x M12; Moulded body: stainless steel (1.4301 / 304)20.4-26.4 DC; ("supply class 2" to cULus)-codable targetwashers: 4cover caps: 8

Loading...

  1. 1

Basic information

Output Data interface type C class 2 Hysteresis(%) 20 Electrical Design PNP
Materials PA Current Consumption(mA) < 50 Protection Class III
Application class C to EN 60654-1 weatherproof application Max. Capacitive Load Ci"max(nF) 200 No-Load Current(mA) 30
Ambient Temperature(°C) -25-70 Reverse Polarity Protection Yes Type of Operation permanent operation
Output Function 2 x OSSD, 1 x PNP Switching Frequency DC(Hz) 1 Safe Switching-Off Distance S(ar)(mm) 16
Operating Current(mA) 40-700 Short-Circuit Protection Yes Housing rectangular
Tightening Torque(Nm) 0.8-2 Max. Leakage Current(mA) 0.5 Permanent Current Rating of Switching Output DC(mA) 50
Max. Power-On Delay Time(ms) 1500 Overload Protection Yes Mounting non-flush mountable
Sensing Range(mm) 12; (with defined actuator) Repeatability Analogue Output(%) ≤ 10; (% Sn) Rated Insulation Voltage(V) 32
Dimensions(mm) 72 x 18 x 25 Display Function: 1 x LED, (ACT)
input
1 x LED, (IN)
Output
1 x LED, (OUT)
operation: 1 x LED, (PWR)

Tech Support