Technical Data:

Max. Current Load per OSSD Output: 400; (24 V) mA

Protection: IP 65; IP 67; IP 69K; (with protective tube: IP 69K)

Power-On Delay Time: < 2 s

Materials: thermowell: PMMA transparent; Protective cap: POM; clamp: stainless steel (1.4404 / 316L); Sealing: silicone

Wave Length: 950 nm


Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

OY450S

Part Number
OY450S
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Max. Current Load per OSSD Output
(mA)
Protection Power-On Delay Time
(s)
Materials Wave Length
(nm)
Current Consumption
(mA)
Protective Function Application Electrical Connection - Transmitter Floating Blanking Storage Temperature
(°C)
Resolution (Detection Capacity D)
(mm)
Ambient Temperature
(°C)
Protection Area Width (Low Light Intensity)
(m)
Length
(mm)
Current Consumption Heating
(mA)
Protected Area Height
(mm)
Electrical Connection - Receiver Dimensions
(mm)
Display Protection Area Width (High Light Intensity)
(m)
Accessories (Included)

5,304.12 €

1 4 Days 400; (24 V)IP 65; IP 67; IP 69K; (with protective tube: IP 69K)< 2thermowell: PMMA transparent; Protective cap: POM; clamp: stainless steel (1.4404 / 316L); Sealing: silicone95083|42access prevention hand protection-Cable: 15 m, PVC; 8 x 0.34 mm²--30-20-550-716874171510Cable: 15 m, PVC; Maximum cable length: 100 m; 10 x 0.34 mm²Ø 56 / L = 1687transmitter: 1 x LEDreceiver: 2 x LED3-15-

Loading...

  1. 1

Basic information

Electrical Design PNP Protection Class III Operating Voltage(V) 24 DC
Reverse Polarity Protection Yes Short-Circuit Protection Yes Type of Light Infrared light
Max. Relative Air Humidity(%) 95 Operating Voltage Tolerance(%) 20 Number of OSSD Outputs 2

This page is Safety Light Curtain, part number OY450S.
You can find the detail information about specifications and dimensions on part number OY450S.

Variation of this product

Part Number
OY004S
OY005S
OY006S
OY453S
OY454S
OY801S
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Max. Current Load per OSSD Output
(mA)
Protection Power-On Delay Time
(s)
Materials Wave Length
(nm)
Current Consumption
(mA)
Protective Function Application Electrical Connection - Transmitter Floating Blanking Storage Temperature
(°C)
Resolution (Detection Capacity D)
(mm)
Ambient Temperature
(°C)
Protection Area Width (Low Light Intensity)
(m)
Length
(mm)
Current Consumption Heating
(mA)
Protected Area Height
(mm)
Electrical Connection - Receiver Dimensions
(mm)
Display Protection Area Width (High Light Intensity)
(m)
Accessories (Included)

3,021.13 €

1 4 Days 400; (24 V)IP 65; IP 67< 2Housing: aluminium; front lens: PC95083|42access prevention finger protectionclass C to EN 60654-1 weatherproof applicationConnector: 1 x M12--14-10-550-3663-610Connector: 1 x M12; Maximum cable length: 100 m; for wire cross-section 0.34 mm²663 x 28 x 30LED, yellow
LED, green
LED, red
LED, blue
LED, orange
1-6Mounting bracket: 4
slot nuts: 4
Nuts

3,455.40 €

1 4 Days 400; (24 V)IP 65; IP 67< 2Housing: aluminium; front lens: PC95083|42access prevention finger protectionclass C to EN 60654-1 weatherproof applicationConnector: 1 x M12--14-10-550-3813-760Connector: 1 x M12; Maximum cable length: 100 m; for wire cross-section 0.34 mm²813 x 28 x 30LED, yellow
LED, green
LED, red
LED, blue
LED, orange
1-6Mounting bracket: 4
slot nuts: 4
Nuts

3,891.11 €

1 4 Days 400; (24 V)IP 65; IP 67< 2Housing: aluminium; front lens: PC95083|42access prevention finger protectionclass C to EN 60654-1 weatherproof applicationConnector: 1 x M12--14-10-550-3963-910Connector: 1 x M12; Maximum cable length: 100 m; for wire cross-section 0.34 mm²963 x 28 x 30LED, yellow
LED, green
LED, red
LED, blue
LED, orange
1-6Mounting bracket: 4
slot nuts: 4
Nuts

5,628.23 €

1 4 Days 400; (24 V)IP 65; IP 67; IP 69K; (with protective tube: IP 69K)< 2thermowell: PMMA transparent; Protective cap: POM; clamp: stainless steel (1.4404 / 316L); Sealing: silicone95083|42access prevention hand protection-Cable: 15 m, PVC; 8 x 0.34 mm²--30-20-550-719874171810Cable: 15 m, PVC; Maximum cable length: 100 m; 10 x 0.34 mm²Ø 56 / L = 1987transmitter: 1 x LEDreceiver: 2 x LED3-15-

4,432.12 €

1 4 Days 400; (24 V)IP 65; IP 67< 2Housing: aluminium; front lens: PC95083|42access prevention hand protectionclass C to EN 60654-1 weatherproof applicationConnector: 1 x M12--20-7030-10-550-41863-1810Connector: 1 x M12; Maximum cable length: 100 m; for wire cross-section 0.34 mm²1863 x 28 x 30transmitter: 1 x LEDreceiver: 2 x LED3-12Mounting bracket: 6
slot nuts: 6
Nuts

1,900.72 €

1 4 Days 500; (24 V)IP 65< 18Housing: aluminium; front lens: PC950125|83access prevention finger protectionclass C to EN 60654-1 weatherproof applicationConnector: 1 x M12Yes-140-550-3261-160Connector: 1 x M12; Maximum cable length: 100 m; for wire cross-section 0.34 mm²261 x 35 x 45transmitter: 3 x LED
transmitter: 7-segment LCD display
receiver: 3 x LED
receiver: 7-segment LCD display
0-5Mounting bracket: 4
slot nuts: 4
screws