Manufacturer part number: DN4011
Brand: IFM ELECTRONIC
Price: 187.57 €
Delivery time: 4 Days
Overload Performance: output current constant
Derating: 1.8 (60-70 °C) W/K
Input Current (Nominal Voltage 230 V AC / 50 Hz): 0.68 A
Max. Output Current at Min. Output Voltage: 3.3 A
Protection: -
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
DN4011
Part Number
|
---|
DN4011 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Overload Performance | Derating (W/K) | Input Current (Nominal Voltage 230 V AC / 50 Hz) (A) | Max. Output Current at Min. Output Voltage (A) | Protection | Output Voltage Tolerance (%) | Max. Output Current Peak at Min. Output Voltage (A) | Power-On Delay Time (s) | Max. Residual Ripple (mV) | Mains Buffering Time (Nominal Voltage 120 V AC / 60 Hz) (ms) | Input Voltage DC (V) | Materials | Protection Class | Switch-On Peak Current (Nominal Voltage 230 V AC / 50 Hz) (A) | Reliability of the DC OK Signal | Power Loss (Nominal Voltage 230 V AC / 50 Hz) (W) | Output Voltage (V) | Operating Voltage (V) | Electrical Connection | Switch-On Peak Current (Nominal Voltage 120 V AC / 60 Hz) (A) | Frequency AC (Hz) | Ambient Temperature (°C) | Overvoltage Protection | Mains Buffering Time (Nominal Voltage 230 V AC / 50 Hz) (ms) | Operating Voltage Tolerance 2 (%) | Parallel Connection of Outputs Possible | Power Factor (Nominal Voltage 120 V AC / 60 Hz) | Nominal Frequency AC (Hz) | Type DC-OK Signal | Inrush Current Limitation | Type of Mounting | Number of Output Circuits | External Input Protection | Short-Circuit Protection | Operating Voltage Tolerance (%) | Power Factor (Nominal Voltage 230 V AC / 50 Hz) | Back Feeding Protection (V) | Output Power (Peak) (W) | Max. Output Current Peak at Max. Output Voltage (A) | Efficiency (Nominal Voltage 230 V AC / 50 Hz) (%) | Power Loss (Nominal Voltage 120 V AC / 60 Hz) (W) | Nominal Voltage AC (V) | Series Connection of Outputs Possible | Input Current (Nominal Voltage 120 V AC / 60 Hz) (A) | Input Voltage Range AC (V) | Efficiency (Nominal Voltage 120 V AC / 60 Hz) (%) | Output Power (Permanent) (W) | Max. Power-On Delay Time (ms) | Max. Output Current at Max. Output Voltage (A) | Short-Circuit Proof | Dimensions (mm) | Display | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
187.57 € | 1 | 4 Days | output current constant | 1.8 (60-70 °C) | 0.68 | 3.3 | - | - | 3.3 | - | 50 | 30 | 110-300 | steel sheet | I; (IEC 61140) | 45 | - | 9.1 | Adjustable; output voltage to SELV. PELV | - | - | 23 | 47-64 | -25-70 | Yes; (< 39 DC) | 128 | 20 | - | 0.61 | - | - | Yes | rail; (TH35 (EN 60715)) | 1 | ≤ B-10 A / ≤ C-6 A | - | 10 | 0.56 | 35 | 80 | 2.7 | 89.8 | 11.1 | < 230 | - | 1.24 | 100-240 | 88 | 80 | - | 2.7 | - | 124 x 40 x 122.5 | DC ok 1 x LED |
Loading...
Output Voltage DC(V) | 24-28 | Overload Protection | Yes |
---|
This page is Switched-Mode PSU, part number DN4011.
You can find the detail information about specifications and dimensions on part number DN4011.
Configure
Basic Attributes
Protection
Output Voltage Tolerance(%)
Power-On Delay Time(s)
Reliability of the DC OK Signal
Operating Voltage(V)
Electrical Connection
Parallel Connection of Outputs Possible
Nominal Frequency AC(Hz)
Type DC-OK Signal
Short-Circuit Protection
Series Connection of Outputs Possible
Max. Power-On Delay Time(ms)
Short-Circuit Proof
Overload Performance
Derating(W/K)
Input Current (Nominal Voltage 230 V AC / 50 Hz)(A)
Max. Output Current at Min. Output Voltage(A)
Max. Output Current Peak at Min. Output Voltage(A)
Max. Residual Ripple(mV)
Mains Buffering Time (Nominal Voltage 120 V AC / 60 Hz)(ms)
Input Voltage DC(V)
Materials
Protection Class
Switch-On Peak Current (Nominal Voltage 230 V AC / 50 Hz)(A)
Power Loss (Nominal Voltage 230 V AC / 50 Hz)(W)
Output Voltage(V)
Switch-On Peak Current (Nominal Voltage 120 V AC / 60 Hz)(A)
Frequency AC(Hz)
Ambient Temperature(°C)
Overvoltage Protection
Mains Buffering Time (Nominal Voltage 230 V AC / 50 Hz)(ms)
Operating Voltage Tolerance 2(%)
Power Factor (Nominal Voltage 120 V AC / 60 Hz)
Inrush Current Limitation
Type of Mounting
Number of Output Circuits
External Input Protection
Operating Voltage Tolerance(%)
Power Factor (Nominal Voltage 230 V AC / 50 Hz)
Back Feeding Protection(V)
Output Power (Peak)(W)
Max. Output Current Peak at Max. Output Voltage(A)
Efficiency (Nominal Voltage 230 V AC / 50 Hz)(%)
Power Loss (Nominal Voltage 120 V AC / 60 Hz)(W)
Nominal Voltage AC(V)
Input Current (Nominal Voltage 120 V AC / 60 Hz)(A)
Input Voltage Range AC(V)
Efficiency (Nominal Voltage 120 V AC / 60 Hz)(%)
Output Power (Permanent)(W)
Max. Output Current at Max. Output Voltage(A)
Dimensions(mm)
Display
Filter by standard shipping days
Optional Attributes
Part Number |
---|
DN1030 |
DN1031 |
DN1042 |
DN4012 |
DN4013 |
DN4014 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Overload Performance | Derating (W/K) | Input Current (Nominal Voltage 230 V AC / 50 Hz) (A) | Max. Output Current at Min. Output Voltage (A) | Protection | Output Voltage Tolerance (%) | Max. Output Current Peak at Min. Output Voltage (A) | Power-On Delay Time (s) | Max. Residual Ripple (mV) | Mains Buffering Time (Nominal Voltage 120 V AC / 60 Hz) (ms) | Input Voltage DC (V) | Materials | Protection Class | Switch-On Peak Current (Nominal Voltage 230 V AC / 50 Hz) (A) | Reliability of the DC OK Signal | Power Loss (Nominal Voltage 230 V AC / 50 Hz) (W) | Output Voltage (V) | Operating Voltage (V) | Electrical Connection | Switch-On Peak Current (Nominal Voltage 120 V AC / 60 Hz) (A) | Frequency AC (Hz) | Ambient Temperature (°C) | Overvoltage Protection | Mains Buffering Time (Nominal Voltage 230 V AC / 50 Hz) (ms) | Operating Voltage Tolerance 2 (%) | Parallel Connection of Outputs Possible | Power Factor (Nominal Voltage 120 V AC / 60 Hz) | Nominal Frequency AC (Hz) | Type DC-OK Signal | Inrush Current Limitation | Type of Mounting | Number of Output Circuits | External Input Protection | Short-Circuit Protection | Operating Voltage Tolerance (%) | Power Factor (Nominal Voltage 230 V AC / 50 Hz) | Back Feeding Protection (V) | Output Power (Peak) (W) | Max. Output Current Peak at Max. Output Voltage (A) | Efficiency (Nominal Voltage 230 V AC / 50 Hz) (%) | Power Loss (Nominal Voltage 120 V AC / 60 Hz) (W) | Nominal Voltage AC (V) | Series Connection of Outputs Possible | Input Current (Nominal Voltage 120 V AC / 60 Hz) (A) | Input Voltage Range AC (V) | Efficiency (Nominal Voltage 120 V AC / 60 Hz) (%) | Output Power (Permanent) (W) | Max. Power-On Delay Time (ms) | Max. Output Current at Max. Output Voltage (A) | Short-Circuit Proof | Dimensions (mm) | Display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
120.37 € | 1 | 4 Days | - | 2% / K (> 60° C) | - | 1.25 | IP 20 | - | - | < 255 | 50 | - | - | PC ABS | II; (IEC 61140) | - | 24 V DC (30 mA) | - | Adjustable | - | cage clamps: | - | - | 0-70 | - | 120 | - | - | - | 47-63 | - | - | rail; (TH35 (EN 60715); free space for convection cooling 30 mm) | 1 | 10 A; B | - | 10 | - | - | - | - | 84 | - | < 230 | - | - | 100-240 | - | - | 255 | - | Yes | 90 x 45 x 100 | DC ok 1 x LED, green | ||
142.65 € | 1 | 4 Days | - | 2% / K (> 60° C) | - | 2.5 | IP 20 | - | - | < 380 | 50 | - | - | PC ABS | II; (IEC 61140) | - | 24 V DC (30 mA) | - | Adjustable | - | cage clamps: | - | - | 0-70 | - | 90 | - | - | - | 47-63 | - | - | rail; (TH35 (EN 60715); free space for convection cooling 30 mm) | 1 | 10 A; B | - | 10 | - | - | - | - | 88 | - | < 230 | - | - | 100-240 | - | - | 380 | - | Yes | 90 x 45 x 100 | DC ok 1 x LED, green | ||
104.74 € | 1 | 4 Days | output current constant | 3 (55-70 °C) | 1.06 | 5 | - | - | 6 | - | 100 | - | - | PC | I; (IEC 61140) | 28 | - | 12.6 | Adjustable; output voltage to SELV. PELV | - | - | - | 47-63 | -10-70 | Yes; (< 34 V DC) | 60 | - | No | - | - | - | - | rail; (TH35 (EN 60715)) | 1 | ≤ B-10 A / ≤ C-6 A | - | 10 | 0.54 | 35 | - | 5.1 | 90.5 | - | 230 | Yes | - | 200-240 | - | 120 | - | 4.3 | Yes | 124 x 39 x 129 | DC ok 1 x LED | ||
248.49 € | 1 | 4 Days | output current constant | - | - | 5 | - | - | 6 | - | - | - | - | steel sheet | I; (IEC 61140) | - | - | - | Adjustable; output voltage to SELV. PELV | automatic range selection | - | - | 47-64 | -25-70 | Yes; (< 39 DC) | - | 10 | No | - | - | - | - | rail; (TH35 (EN 60715)) | - | - | - | 10 | - | - | 144 | 5.1 | - | - | < 230 | Yes | - | 100-120 / 200-240; (automatic range selection) | - | 120 | - | 4.3 | Yes | 124 x 40 x 122.5 | DC ok 1 x LED | ||
324.56 € | 1 | 4 Days | output current constant | - | - | 10 | - | - | 12 | - | - | - | - | steel sheet | I; (IEC 61140) | - | 60 V DC (0.3 A) / 30 V DC (1 A) / 30 V AC (0.5 A) | - | Adjustable; output voltage to SELV. PELV | automatic range selection | - | - | 47-64 | -25-70 | Yes; (< 39 DC) | - | 10 | - | - | 50-60 | relay output | - | rail; (TH35 (EN 60715)) | - | - | - | 10 | - | - | 288 | 10.3 | - | - | < 230 | - | - | 100-120 / 200-240 | - | 240 | - | 8.6 | Yes | 124 x 62 x 122.5 | DC ok 1 x LED | ||
423.63 € | 1 | 4 Days | Hiccup mode; In the event of overload / short circuit, the output alternately supplies continuous power for 2 s and then switches off for 18 s. | - | - | 20 | - | - | 24 | - | - | - | - | steel sheet | I; (IEC 61140) | - | 60 V DC (0.3 A) / 30 V DC (1 A) / 30 V AC (0.5 A) | - | Adjustable; output voltage to SELV. PELV | - | screw terminals: | - | 47-64 | -25-70 | Yes; (< 32 DC) | - | - | - | - | - | relay output | - | rail; (TH35 (EN 60715)) | - | - | - | 15-10 | - | - | 576 | 20.6 | - | - | < 230 | - | - | 100-240 | - | 480 | - | 17.1 | Yes | 124 x 65 x 132.5 | DC ok 1 x LED |