Vortex Flow Meter (SV7614)

Vortex Flow Meter SV7614

Product Details:

Manufacturer part number: SV7614

Brand: IFM ELECTRONIC

Price: 462.12

Delivery time: 4 Days


Technical Data:

Number of Inputs and Outputs: Number of analogue outputs: 2

Protection: -

Power-On Delay Time: < 3 s

Electrical Design: -

Cavitation: -


Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

SV7614

Part Number
SV7614
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Number of Inputs and Outputs Protection Power-On Delay Time
(s)
Electrical Design Cavitation Materials Current Consumption
(mA)
Pressure Rating
(psi)
Electrical Connection - Plug Analogue Current Output
(mA)
Process Connection Accuracy
(K)
Storage Temperature
(°C)
Measuring Element Operating Voltage
(V)
Electrical Connection Min. Bursting Pressure
(MPa)
Ambient Temperature
(°C)
Reverse Polarity Protection Number of Analogue Outputs Output Function Medium Temperature
(°C)
Total Number of Outputs Repeatability Max. Load
(Ω)
Medium Temperature
(°F)
Number of Digital Outputs Output Signal Short-Circuit Protection Max. Voltage Drop Switching Output DC
(V)
Communication Interface Tightening Torque
(Nm)
Measuring Range Application Media Permanent Current Rating of Switching Output DC
(mA)
Pressure Rating
(MPa)
Overload Protection Ambient Temperature
(°F)
Accuracy (In the Measuring Range) IO-Link Revision Installation Required Master Port Type Materials (Wetted Parts) Transmission Type Min. Bursting Pressure
(bar)

462.12 €

1 4 Days Number of analogue outputs: 2-< 3--stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U< 30174-4-20threaded connection 3/4"NPT DN20± 1--18-30 DCConnector: 1 x M12; Contacts: gold-plated--Yes2--2± 0.5 % MEW50014-194-Analogue signalYes--3080-1585 gph
1.3-26.4 gpm
water--Yes32-140± 2 % MEW---stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM--

Loading...

  1. 1

Basic information

Pressure Rating(bar) 12 Protection Class III Application For industrial applications
Special Feature Gold-plated contacts Min. Insulation Resistance(MΩ) 100; (500 V DC)

This page is Vortex Flow Meter, part number SV7614.
You can find the detail information about specifications and dimensions on part number SV7614.

Variation of this product

Part Number
SV4050
SV4150
SV4200
SV4204
SV8050
SV8150
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Number of Inputs and Outputs Protection Power-On Delay Time
(s)
Electrical Design Cavitation Materials Current Consumption
(mA)
Pressure Rating
(psi)
Electrical Connection - Plug Analogue Current Output
(mA)
Process Connection Accuracy
(K)
Storage Temperature
(°C)
Measuring Element Operating Voltage
(V)
Electrical Connection Min. Bursting Pressure
(MPa)
Ambient Temperature
(°C)
Reverse Polarity Protection Number of Analogue Outputs Output Function Medium Temperature
(°C)
Total Number of Outputs Repeatability Max. Load
(Ω)
Medium Temperature
(°F)
Number of Digital Outputs Output Signal Short-Circuit Protection Max. Voltage Drop Switching Output DC
(V)
Communication Interface Tightening Torque
(Nm)
Measuring Range Application Media Permanent Current Rating of Switching Output DC
(mA)
Pressure Rating
(MPa)
Overload Protection Ambient Temperature
(°F)
Accuracy (In the Measuring Range) IO-Link Revision Installation Required Master Port Type Materials (Wetted Parts) Transmission Type Min. Bursting Pressure
(bar)

120.60 €

1 4 Days Number of analogue outputs: 1IP 65< 2-P(absolute) discharge / P(difference) > 5.5 to avoid cavitationPA 6T---4-20; (Q [l/min] = 0.938 x (I - 4 mA))threaded connection G 1/2 DN8± 0.3 ± 0.005 x T-30-851 x Pt 1000; (to DIN EN 60751, class B)8-33 DCConnector: 1 x M12; Contacts: gold-plated2.5-15-85-1--40-10010.2; (% of the final value)< (Ub - 8 V) / 20 mA; Ub = 24 V: 800--Analogue signal---120.9-15 l/min
0.133-2.21 m/s|0.9-15 l/min
0.133-2.21 m/s
water; glycol solutions; coolants-1.2--Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water)-connection to pipe by means of an adapter-ETFE; PA 6T; FKM-25

120.60 €

1 4 Days Number of analogue outputs: 1-< 2--PA 6T---4-20; (Q [l/min] = 0.938 x (I - 4 mA))threaded connection G 1/2 DN8± 0.3 ± 0.005 x T-1 x Pt 1000; (to DIN EN 60751, class B)8-33 DCConnector: 1 x M12; Contacts: gold-plated2.5-15-85-1--40-10010.2; (% of the final value)< (Ub - 8 V) / 20 mA; Ub = 24 V: 800--Analogue signal---120.9-15 l/min
0.133-2.21 m/s|0.9-15 l/min
0.133-2.21 m/s
water; glycol solutions; coolants-1.2--Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water)-connection to pipe by means of an adapter-ETFE; PA 6T; EPDM-25

405.14 €

1 4 Days Number of digital outputs: 2-< 3PNP/NPN-stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U< 30---threaded connection G 1/2 DN8± 1--18-30 DCConnector: 1 x M12; Contacts: gold-plated-0-60Yes-normally open / normally closed; (parameterisable)-10-902± 0.5 % MEW--2Switching signal; frequency signal; IO-Link; (configurable)Yes2.5IO-Link301-20 l/min
0.06-1.2 m³/h
water1001.2Yes-± 2 % MEW1.1-Astainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKMCOM2 (38.4 kBaud)-

412.48 €

1 4 Days Number of analogue outputs: 2-< 3--stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U< 30--4-20threaded connection G 1/2 DN8± 1--18-30 DCConnector: 1 x M12; Contacts: gold-plated-0-60Yes2--10-902± 0.5 % MEW500--Analogue signalYes--301-20 l/min
0.06-1.2 m³/h
water-1.2Yes-± 2 % MEW---stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM--

136.83 €

1 4 Days Number of analogue outputs: 1IP 65< 2-P(absolute) discharge / P(difference) > 5.5 to avoid cavitationPA 6T---4-20; (water: Q [l/min] = 9.375 x (I - 4 mA); water-glycol: Q [l/min] = 9.375 x (I - 4 mA) - Qo see Figure 2)threaded connection G 1 1/4 DN25± 0.3 ± 0.005 x T-30-851 x Pt 1000; (to DIN EN 60751, class B)8-33 DCConnector: 1 x M12; Contacts: gold-plated2.5-15-85-1--40-10010.2; (% of the final value)< (Ub - 8 V) / 20 mA; Ub = 24 V: 800--Analogue signal---159-150 l/min
0.283-4.709 m/s
Internal heating temperature probe: 1 K/mW
Measuring range [°C]: -40-100|9-150 l/min
0.283-4.709 m/s
water; glycol solutions; coolants-1.2--Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water)-connection to pipe by means of an adapter-ETFE; PA 6T; FKM-25

136.83 €

1 4 Days Number of analogue outputs: 1-< 2--PA 6T---4-20; (water: Q [l/min] = 9.375 x (I - 4 mA); water-glycol: Q [l/min] = 9.375 x (I - 4 mA) - Qo see Figure 2)threaded connection G 1 1/4 DN25± 0.3 ± 0.005 x T-1 x Pt 1000; (to DIN EN 60751, class B)8-33 DCConnector: 1 x M12; Contacts: gold-plated2.5-15-85-1--40-10010.2; (% of the final value)< (Ub - 8 V) / 20 mA; Ub = 24 V: 800--Analogue signal---159-150 l/min
0.283-4.709 m/s
Internal heating temperature probe: 1 K/mW
Measuring range [°C]: -40-100|9-150 l/min
0.283-4.709 m/s
water; glycol solutions; coolants-1.2--Q < 50 % MEW: < 1 % MEW / Q > 50 % MEW: < 2 % MW; (water)-connection to pipe by means of an adapter-ETFE; PA 6T; EPDM-25