[Specifications] ・Voltage source: 24 V DC nominal, 18 to 30 V DC ・Constant current diode: 2 to 10 mA, recommended 4 mA ・Electrical noise: - 2.0 Hz: 20 μg//Hz ・Output impedance: <1000 ・Bias output voltage: 12V DC ・Grounding: Case isolated, internally shielded
[Features] ・For use with all SKF portable data collection instruments ・Rugged, economical and all around general purpose sensor ・100 mV/g sensitivity to optimize use in multiple applications ・Exceptional bias voltage (BV) stability at elevated temperatures ・Designed for exceptional low noise level over a wide temperature range ・Meets CE, EMC requirements ・Two mounting studs (1/4–28 and M8 × 1.25) provided ・Corrosion resistant and hermetically sealed for installation in high humidity areas ・Reverse polarity wiring protection
[Specifications] ・series: TMEH ・Suitable oil types: mineral and synthetic oils
[Features] ・Hand-held and user friendly ・Numerical readout to facilitate trending · Can store calibration (good oil) in its memory ・Shows changes in oil condition affected by such things as: – Water content - Fuel contamination - Metallic content - Oxidation